<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>10.8.5 | RJG, Inc.</title>
	<atom:link href="https://rjginc.com/product-tag/10-8-5/feed/" rel="self" type="application/rss+xml" />
	<link>https://rjginc.com</link>
	<description>Award-Winning Training and Technology Company</description>
	<lastBuildDate>Tue, 05 Sep 2023 12:27:08 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.7</generator>

<image>
	<url>https://rjginc.com/wp-content/uploads/2021/10/cropped-group@3x-100x100.png</url>
	<title>10.8.5 | RJG, Inc.</title>
	<link>https://rjginc.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>eDART Software Version: 10.8.5</title>
		<link>https://rjginc.com/product/edart-software-version-10-8-5/</link>
		
		<dc:creator><![CDATA[Mike Novak]]></dc:creator>
		<pubDate>Tue, 05 Sep 2023 12:26:50 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/?post_type=product&#038;p=260054</guid>

					<description><![CDATA[This document covers only the series v10 releases. September, 2023 What&#8217;s New in Release &#8216;10.8.5&#8217; Bug Fixes Fixed an issue with SG/LX and PZ/LX adapters >20******** [2020-year date], where a user could assign the sensors but would not be able to add them on the Cycle Graph, nor be able to review them on the [&#8230;]]]></description>
										<content:encoded><![CDATA[<div>
<p>This document covers only the series v10 releases. </p>
<p><i>September, 2023</i></p>
<h2>What&#8217;s New in Release &#8216;10.8.5&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed an issue with SG/LX and PZ/LX adapters >20******** [2020-year date], where a user could assign the sensors but would not be able to add them on the Cycle Graph, nor be able to review them on the Raw Data Viewer.</li>
<li>Fixed an issue with ID7 and OR2 modules >20******** [2020-year date], where the user may be able to assign the modules; however, Raw Data Viewer would report incorrect values for the modules.</li>
</ul>
<p><i>February 24, 2022</i></p>
<h2>What&#8217;s New in Release &#8216;10.8.4&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed an assignment issue with multichannel strain gage adapters (MCSG), where, if a user added then removed a sensor, it<br />
      could potentially cause the system to lock up before a reboot.</li>
</ul>
<p><i>August 3, 2021</i></p>
<h2>What&#8217;s New in Release &#8216;10.8.3&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed an issue with the Raw Data Viewer’s Port Diagnostics reporting negative values on devices which contained a serial<br />
      number greater than 20******** [2020-year date].</li>
</ul>
<p><i>June 10, 2021</i></p>
<h2>What&#8217;s New in Release &#8216;10.8.2&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Improved performance when selecting a Machine, Mold or Setup when there are a large number of configurations in the pick list.</li>
</ul>
<p><i>June 14, 2017</i></p>
<h2>What&#8217;s New in Release &#8216;10.8.1&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed Lynx™ communication issue where upon Job Start, under certain sensor combinations, communication could be<br />
      interrupted.  When system restored communication, some sensors would be missing.</li>
</ul>
<p><a name="_Hlk485215776"><i>February 23, 2017</i></a></p>
<h2><a name="_Hlk485215738">What&#8217;s New in Release &#8216;10.8&#8217;</a></h2>
<h3><a name="_Hlk485215806">Bug<br />
    Fixes</a></h3>
<ul>
<li>Support for new 4 Channel Piezo adapters</li>
<li> Support for The Hub integration, still requires<br />
      patch to enable</li>
</ul>
<p><i>November 16, 2016</i></p>
<h2>What&#8217;s New in Release &#8216;10.7.9&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Support for 6mm Strain Gage sensors </li>
<li>Fixed bug where initial offset was always be set to zero on strain gage sensors </li>
</ul>
<p><i>October 10, 2016</i></p>
<h2>What&#8217;s New in Release &#8216;10.7.8&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Can assign IA1 modules on Machine setup for coolant flow and temperature </li>
<li>When overwriting template in cycle graph the dialog would not close automatically </li>
<li>Audit log was no longer updating because the log file name was changed </li>
<li>Various translation fixes </li>
</ul>
<p><i>September 2, 2016</i></p>
<h2>What&#8217;s New in Release &#8216;10.7.7&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>The Balance Viewer in the Cycle Graph did not show any data in other languages </li>
<li>You can now see the date that a template was saved when selecting a template in the Cycle Graph </li>
</ul>
<p><i>August 1, 2016</i></p>
<h2>What&#8217;s New in Release &#8216;10.7.6&#8217;</h2>
<h3>New Features</h3>
<ul>
<li>A user can now assign multiple flow meters in the machine setup and input an id for each sensor </li>
</ul>
<p><i>July 1, 2016</i></p>
<h2>What&#8217;s New in Release &#8216;10.7.5&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed &#8216;Process Setup&#8217; disappearance issue. </li>
</ul>
<p><i>June 6, 2016</i></p>
<h2>What&#8217;s New in Release &#8216;10.7.4&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed regression of not being able to assign multi channel piezo adapters with missing plate id </li>
<li>Fixed bug with V-&gt;P where changes would be reverted if you changed a value by more than 10% </li>
<li>Fixed bug where if you started a job with an unassigned sensor it would have incorrect default values set when you<br />
      configured it later </li>
<li>Fixed bug with process names that are longer than 28 charaters, previously it would make the home screen progressively slower and have blank entries </li>
<li>It will now not show the multichannel adapter in the mold configuration if the plate id is missing, there was previously still<br />
      path to get both to show </li>
<li>Fixed bug with analog inputs where if they are converted from v9 setup they would have a full scale of 0 </li>
</ul>
<p><i>Apr 11, 2016</i></p>
<h2>What&#8217;s New in Release &#8216;10.7.3&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Set Screw Bottom is no longer skipped when<br />
      starting a job after a reboot </li>
<li>Fixed the Job Started Output so that the module<br />
      channel activates when a job is started </li>
<li>Removed the annotator and replaced it with a<br />
      cycle values display on the cycle graph </li>
<li>Cavity Fill Time Balance Percentage added as a<br />
      summary variable. </li>
<li>Cushion can be calculated with analog input<br />
      modules </li>
<li>V-P layout improved for better visibility of the<br />
      cycle graph window </li>
<li>Mini Mega MCSG Adapter Support </li>
<li>i icon missing for<br />
      Sensors setup </li>
<li>Analog input sensors used for stroke now allow 0<br />
      and 10 V to be swapped between screw bottom and full shot </li>
<li>Balance Viewer Sensor Name display as cavity<br />
      names instead of aliases </li>
<li>Corrupt file and directory detection and handing </li>
</ul>
<p><i>Dec 3, 2015</i></p>
<h2>What&#8217;s New in Release &#8216;10.7.2&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed bug with N type themocouple sensors that would cause them to be configured as plastic pressure instead of<br />
      temperature </li>
<li>Fixed bug introduced in 10.7.1 that would not<br />
      show sensors on the Mold Outputs configuration page </li>
</ul>
<h2>What&#8217;s New in Release &#8216;10.7.1&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Fixed bug where you could assign MCSG sensor<br />
      when a plate was not attached which would cause sensor location to block when<br />
      starting a job </li>
<li>Fixed bug where sensors would not correctly<br />
      populate the unused sensor list </li>
<li>Fixed bug where mega multi<br />
      channel sensor may not show up as connected if connected after you start<br />
      editing the mold </li>
<li>Changed the way the Multi channel adapter<br />
      display the plate that is attached, it now shows both the adapter serial number<br />
      and plate id, when a sensor is configured in a location is only shows the plate<br />
      id </li>
<li>Fixed that you could not show summary variables<br />
      or add alarms for Coolant Flow Temperature sensors </li>
<li>Added support for new mega SG/LX8-S-ID </li>
</ul>
<p><i>Aug 6, 2015</i></p>
<h2>What&#8217;s New in Release &#8216;10.7&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Cycle Graph pop-up annotator replaced by fixed<br />
      location cycle values and balance viewer. </li>
<li>Excessive Rejects clear function now has it&#8217;s own security item called &quot;Excessive Rejects&quot;; was previously bundled in with the process security. </li>
</ul>
<p><i>July 8, 2015</i></p>
<h2>What&#8217;s New in Release &#8216;10.6.9&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>Inject Enable will now show the user login screen when you attempt to enable injection. A new security entry was added for Inject Enable </li>
<li>Previously only administrators could reset and disable Excessive Rejects, now user with Process rights have access </li>
<li>Sensors should no longer show invalid messages while starting a job unless they are legitimately invalid or missing </li>
<li>On the stability match windows entries should now follow the same rules that the summary graph selector uses to determine where they are displayed </li>
<li>On the Alarm Count window the scrollbar would not allow you to scroll past nine entries, this now works </li>
<li>On the cycle graph, template control windows should open in consistent positions </li>
<li>Long text should no longer be cutoff on the Alarm Settings page </li>
<li>Long text should no longer be cutoff on the Stability Match pages </li>
<li>Long text should no longer be cutoff on the Cycle Alarm indicators </li>
<li>Long text should no longer be cutoff on the Alarm Count page </li>
<li>Values on Cycle Alarm indicators are now displayed in current units and the units are shown </li>
<li>On the Diagnostic page sensor out of calibration errors now don&#8217;t cause sensors to show a warning symbol </li>
</ul>
<h2>What&#8217;s New in Release &#8216;10.6.8.3&#8217;</h2>
<h3>Bug Fixes</h3>
<ul>
<li>When placing multiple sensors in a single location in a cavity it was not reloading the data correctly on reopening the mold setup. This would lead to sensors not being configured correctly if the<br />
      setup was then saved. It will now have the right settings. </li>
<li>When multiple sensors where placed in a single location the ordering would change when configuring sensors, this was<br />
      confusing. It no longer does this. </li>
</ul>
<h2>What&#8217;s New in Release &#8216;10.6.8.2&#8217;</h2>
<h3>Improvements and<br />
    Changes</h3>
<ul>
<li>Support for Peak Ejector Force Optional Tool. </li>
<li>Added support for dual analog flow/temperature IA2-M-FT. </li>
</ul>
<h3>Bug Fixes</h3>
<ul>
<li>Fix for Valve Gate always defaulting to &quot;Open Gate&quot;. </li>
<li>Fix for job started output, now on when the job<br />
      is running and off when the job is started. </li>
<li>Template Match Values are now displayed. </li>
<li>Home menu now disappears when focus is lost. </li>
<li>Disallows testing Job Started, Job Down and Job Running outputs while the job is running. </li>
</ul></div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/?utm_source=w3tc&utm_medium=footer_comment&utm_campaign=free_plugin

Page Caching using Disk: Enhanced 

Served from: rjginc.com @ 2026-10-24 20:01:15 by W3 Total Cache
-->