<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>10.8.4 | RJG, Inc.</title>
	<atom:link href="https://rjginc.com/product-tag/10-8-4/feed/" rel="self" type="application/rss+xml" />
	<link>https://rjginc.com</link>
	<description>Award-Winning Training and Technology Company</description>
	<lastBuildDate>Wed, 23 Nov 2022 10:02:46 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://rjginc.com/wp-content/uploads/2021/10/cropped-group@3x-100x100.png</url>
	<title>10.8.4 | RJG, Inc.</title>
	<link>https://rjginc.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>eDART Software Version: 10.8.4</title>
		<link>https://rjginc.com/product/edart-software-version-10-8-4/</link>
		
		<dc:creator><![CDATA[Mike Novak]]></dc:creator>
		<pubDate>Tue, 08 Mar 2022 20:05:27 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/?post_type=product&#038;p=238144</guid>

					<description><![CDATA[<div class="modal-header">
<h3 id="note-modal-title">Important Note</h3>
</div>
<div class="modal-body">
<div id="note-content">

The <em>eDART</em> must be at 10.7 or above before this update can be applied.

The EDM Upgrade 2.6.1 is REQUIRED in order for the <em>eDART</em>s to share security files and default files automatically. Please read how the new automatic copy will work with this upgrade. <a href="https://rjginc.com/wp-content/uploads/2018/10/File_Version_Control.pdf">The attached file is the read me file.</a>

</div>
</div>]]></description>
										<content:encoded><![CDATA[<div>
<p>This document covers only the series v10 releases.</p>
<p style="text-align: right;" align="right"><i>February 24, 2022</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.8.4&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Fixed an assignment issue with multichannel strain gage adapters (MCSG), where, if a user added then removed a sensor, it could potentially cause the system to lock up before a reboot.</p>
<p style="text-align: right;" align="right"><i>August 3, 2021</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.8.3&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Fixed an issue with the Raw Data Viewer’s Port Diagnostics reporting negative values on devices which contained a serial number greater than 20******** [2020-year date].</p>
<p style="text-align: right;" align="right"><i>June 10, 2021</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.8.2&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Improved performance when selecting a Machine, Mold or Setup when there are a large number of configurations in the pick list.</p>
<p style="text-align: right;" align="right"><i>June 14, 2017</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.8.1&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Fixed Lynx™ communication issue where upon Job Start, under certain sensor combinations, communication could be interrupted. When system restored communication, some sensors would be missing.</p>
<p style="text-align: right;" align="right"><a name="_Hlk485215776"></a><i>February 23,<br />
2017</i></p>
<h2 style="text-align: center;" align="center"><a name="_Hlk485215738"></a>What&#8217;s New in Release &#8216;10.8&#8217;</h2>
<h3><a name="_Hlk485215806"></a>Bug Fixes</h3>
<p>·         Support for new 4 Channel Piezo adapters</p>
<p>·         Support for The Hub integration, still requires patch to enable</p>
<p style="text-align: right;" align="right"><i>November 16, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.9&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Support for 6mm Strain Gage sensors</p>
<p>·         Fixed bug where initial offset was always be set to zero on strain gage sensors</p>
<p style="text-align: right;" align="right"><i>October 10, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.8&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Can assign IA1 modules on Machine setup for coolant flow and temperature</p>
<p>·         When overwriting template in cycle graph the dialog would not close automatically</p>
<p>·         Audit log was no longer updating because the log file name was changed</p>
<p>·         Various translation fixes</p>
<p style="text-align: right;" align="right"><i>September 2, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.7&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         The Balance Viewer in the Cycle Graph did not show any data in other languages</p>
<p>·         You can now see the date that a template was saved when selecting a template in the Cycle Graph</p>
<p style="text-align: right;" align="right"><i>August 1, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.6&#8217;</h2>
<h3>New Features</h3>
<p>·         A user can now assign multiple flow meters in<br />
the machine setup and input an id for each sensor</p>
<p style="text-align: right;" align="right"><i>July 1, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.5&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Fixed &#8216;Process Setup&#8217; disappearance issue.</p>
<p style="text-align: right;" align="right"><i>June 6, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.4&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Fixed regression of not being able to assign multi channel piezo adapters with missing plate id</p>
<p>·         Fixed bug with V-&gt;P where changes would be reverted if you changed a value by more than 10%</p>
<p>·         Fixed bug where if you started a job with an unassigned sensor it would have incorrect default values set when you configured it later</p>
<p>·         Fixed bug with process names that are longer than 28 charaters, previously it would make the home screen progressively slower and have blank entries</p>
<p>·         It will now not show the multichannel adapter in the mold configuration if the plate id is missing, there was previously still path to get both to show</p>
<p>·         Fixed bug with analog inputs where if they are converted from v9 setup they would have a full scale of 0</p>
<p style="text-align: right;" align="right"><i>Apr 11, 2016</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.3&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Set Screw Bottom is no longer skipped when starting a job after a reboot</p>
<p>·         Fixed the Job Started Output so that the module channel activates when a job is started</p>
<p>·         Removed the annotator and replaced it with a cycle values display on the cycle graph</p>
<p>·         Cavity Fill Time Balance Percentage added as a summary variable.</p>
<p>·         Cushion can be calculated with analog input modules</p>
<p>·         V-P layout improved for better visibility of the cycle graph window</p>
<p>·         Mini Mega MCSG Adapter Support</p>
<p>·         i icon missing for Sensors setup</p>
<p>·         Analog input sensors used for stroke now allow 0 and 10 V to be swapped between screw bottom and full shot</p>
<p>·         Balance Viewer Sensor Name display as cavity names instead of aliases</p>
<p>·         Corrupt file and directory detection and handing</p>
<p style="text-align: right;" align="right"><i>Dec 3, 2015</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.2&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Fixed bug with N type themocouple sensors that would cause them to be configured as plastic pressure instead of temperature</p>
<p><span style="font-size: 10.0pt; font-family: Symbol;">·         Fixed bug introduced in 10.7.1 that would not show sensors on the Mold Outputs configuration page </span></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7.1&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Fixed bug where you could assign MCSG sensor when a plate was not attached which would cause sensor location to block when starting a job</p>
<p>·         Fixed bug where sensors would not correctly populate the unused sensor list</p>
<p>·         Fixed bug where mega multi channel sensor may not show up as connected if connected after you start<br />
editing the mold</p>
<p>·         Changed the way the Multi channel adapter display the plate that is attached, it now shows both the adapter serial number and plate id, when a sensor is configured in a location is only shows the plate<br />
id</p>
<p>·         Fixed that you could not show summary variables or add alarms for Coolant Flow Temperature sensors</p>
<p>·         Added support for new mega SG/LX8-S-ID</p>
<p style="text-align: right;" align="right"><i>Aug 6, 2015</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.7&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Cycle Graph pop-up annotator replaced by fixed location cycle values and balance viewer.</p>
<p>·         Excessive Rejects clear function now has it&#8217;s own security item called &#8220;Excessive Rejects&#8221;; was previously bundled in with the process security.</p>
<p style="text-align: right;" align="right"><i>July 8, 2015</i></p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.6.9&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         Inject Enable will now show the user login screen when you attempt to enable injection. A new security entry was added for Inject Enable</p>
<p>·         Previously only administrators could reset and disable Excessive Rejects, now user with Process rights have access</p>
<p>·         Sensors should no longer show invalid messages while starting a job unless they are legitimately invalid or missing</p>
<p>·         On the stability match windows entries should now follow the same rules that the summary graph selector uses to determine where they are displayed</p>
<p>·         On the Alarm Count window the scrollbar would not allow you to scroll past nine entries, this now works</p>
<p>·         On the cycle graph, template control windows should open in consistent positions</p>
<p>·         Long text should no longer be cutoff on the Alarm Settings page</p>
<p>·         Long text should no longer be cutoff on the Stability Match pages</p>
<p>·         Long text should no longer be cutoff on the Cycle Alarm indicators</p>
<p>·         Long text should no longer be cutoff on the Alarm Count page</p>
<p>·         Values on Cycle Alarm indicators are now displayed in current units and the units are shown</p>
<p>·         On the Diagnostic page sensor out of calibration errors now don&#8217;t cause sensors to show a warning symbol</p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.6.8.3&#8217;</h2>
<h3>Bug Fixes</h3>
<p>·         When placing multiple sensors in a single location in a cavity it was not reloading the data correctly on reopening the<br />
mold setup. This would lead to sensors not being configured correctly if the setup was then saved. It will now have the right settings.</p>
<p>·         When multiple sensors where placed in a single location the ordering would change when configuring sensors, this was confusing. It no longer does this.</p>
<h2 style="text-align: center;" align="center">What&#8217;s New in Release &#8216;10.6.8.2&#8217;</h2>
<h3>Improvements and Changes</h3>
<p>·         Support for Peak Ejector Force Optional Tool.</p>
<p>·         Added support for dual analog flow/temperature IA2-M-FT.</p>
<h3>Bug Fixes</h3>
<p>·         Fix for Valve Gate always defaulting to &#8220;Open Gate&#8221;.</p>
<p>·         Fix for job started output, now on when the job is running and off when the job is started.</p>
<p>·         Template Match Values are now displayed.</p>
<p>·         Home menu now disappears when focus is lost.</p>
<p>·         Disallows testing Job Started, Job Down and Job Running outputs while the job is running.</p>
</div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/?utm_source=w3tc&utm_medium=footer_comment&utm_campaign=free_plugin

Page Caching using Disk: Enhanced 

Served from: rjginc.com @ 2026-07-04 19:15:09 by W3 Total Cache
-->