<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Modules | RJG, Inc.</title>
	<atom:link href="https://rjginc.com/product-category/auxiliary-hardware/modules/feed/" rel="self" type="application/rss+xml" />
	<link>https://rjginc.com</link>
	<description>Award-Winning Training and Technology Company</description>
	<lastBuildDate>Thu, 27 Jun 2024 14:30:54 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://rjginc.com/wp-content/uploads/2021/10/cropped-group@3x-100x100.png</url>
	<title>Modules | RJG, Inc.</title>
	<link>https://rjginc.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>IA2-M-DFT</title>
		<link>https://rjginc.com/product/ia2-m-dft/</link>
		
		<dc:creator><![CDATA[Mike Novak]]></dc:creator>
		<pubDate>Tue, 11 Feb 2020 19:53:55 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/?post_type=product&#038;p=219674</guid>

					<description><![CDATA[<table class="product-specs">
<tbody>
<tr>
<td style="width: 50%;" width="50%">All Modules</td>
<td>Max. Temp. (Operating) 140° F</td>
</tr>
<tr>
<td rowspan="3">1 Flow Sensor Input
1 Temperature Sensor Input
Sensor Power</td>
<td>Burger-Brown Flow-Temperature Sensor Interface</td>
</tr>
<tr>
<td>Accuracy ±1%</td>
</tr>
<tr>
<td>Electrically Isolated Inputs</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Lynx Flow-Temperature Sensor Interface  &#8211; Shielded</p>
<p>The IA2-M-DFT Lynx Flow-Temperature Interface Module provides all the inputs and outputs needed to interface RJG&#8217;s process control systems to Smartflow<sup>®</sup>’s TracerVM™ and TracerVM™ with user interface line of flowmeters. This din-rail module is shielded to ensure high quality data even in rugged molding environments.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>OA1-M-V</title>
		<link>https://rjginc.com/product/oa1-m/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:59 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/oa1-m/</guid>

					<description><![CDATA[<table class="product-specs">
<tbody>
<tr>
<td>All Modules</td>
<td>Max. Temp. (Operating) 140° F</td>
</tr>
<tr>
<td rowspan="3">OA1-M-V
1 Analog Output</td>
<td>0-10 VDC</td>
</tr>
<tr>
<td>Accuracy ±1%</td>
</tr>
<tr>
<td>Electrically Isolated Input</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Lynx<sup>™</sup> Analog Output Module  &#8211; Shielded</p>
<p>This isolated, analog output module can be used to interface with any sensor, or input, that accepts a 0-10V DC signal, like plastic and hydraulic pressure input cards. It can also be used as an external machine transfer.</p>
<p>Once mounted, the connectors allow the unit to be interfaced with other Lynx DIN rail modules and RJG&#8217;s process control systems. Each machine panel installation of one or more DIN rail modules requires either an ID7-M-SEQ or a DIN/LX-M to terminate the DIN rail module chain.</p>
<p><strong>Features and benefits:</strong></p>
<ul>
<li>Easier installation and troubleshooting</li>
<li>Increased immunity to interference in electronically noisy environments</li>
<li>Convenient 35 mm DIN rail mounting</li>
<li>Removable/replaceable cables</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>OR2-M</title>
		<link>https://rjginc.com/product/or2-m/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:59 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/or2-m/</guid>

					<description><![CDATA[<table class="product-specs">
<tbody>
<tr>
<td>All Modules</td>
<td>Max. Temp. (Operating) 140° F</td>
</tr>
<tr>
<td rowspan="2">OR2-M
2 Relay Outputs</td>
<td>Contact Rating 1A 30 VDC</td>
</tr>
<tr>
<td>Fused Dry Contacts</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Lynx<sup>™</sup> Dual Relay Output Module  &#8211; Shielded</p>
<p>The dual contact closure output module is designed to be used with RJG&#8217;s process control systems. The module&#8217;s two dry contact outputs can also be configured to implement part containment or transfer a molding machine.</p>
<p>Once mounted, the connectors allow the unit to be interfaced with other Lynx DIN rail modules as well as process control systems. Each machine panel installation of one or more DIN rail modules requires either an ID7-M-SEQ or a DIN/LX-M to terminate the DIN rail module chain.</p>
<p><strong>Features and benefits:</strong></p>
<ul>
<li>Easier installation and troubleshooting</li>
<li>Increased immunity to interference in electronically noisy environments</li>
<li>Convenient 35 mm DIN rail mounting</li>
<li>Easy-to-read status LEDs</li>
<li>Removable/replaceable cables</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>VM Flowmeter &#038; Interface Module</title>
		<link>https://rjginc.com/product/flowmeter/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 18:38:59 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/vm-4-b-40-b/</guid>

					<description><![CDATA[<table style="border-collapse: collapse; text-align: center;" border="0" width="100%" cellpadding="5">
<tbody>
<tr>
<td colspan="5">
<h4><strong>Model Variations by Thread Sizes</strong></h4>
</td>
</tr>
<tr>
<td><strong>VM3</strong></td>
<td><strong>VM4</strong></td>
<td><strong>VM6</strong></td>
<td><strong>VM8</strong></td>
<td><strong>VM12</strong></td>
</tr>
<tr>
<td>3/8"</td>
<td>1/2"</td>
<td>3/4"</td>
<td>1"</td>
<td>1.5"</td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="text-align: left;">
<td colspan="5"><strong>Other variations to choose the right fit:</strong>
<ul>
 	<li>Thread Type</li>
 	<li>Flow Meter Connection</li>
 	<li>Water Flow Selection</li>
 	<li>Display (UI Interface) Option</li>
</ul>
</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>This device is a simple flow meter to measure either the flow, and temperature through the manifold or to individual circuits. When interfaced with RJG&#8217;s process control systems, users can access and use data such as: excessive reject control, summary variables, template values, and summary and cycle values.</p>
<p><strong>What you can do:</strong></p>
<ul>
<li>Determine if the water temperature control unit is delivering the correct temperature needed to make good parts</li>
<li>Reject parts if the flow or temperature doesn&#8217;t meet your set requirements to make a good part</li>
<li>Create a template of the flow or water temperature</li>
<li>Overlay your GPM or temperature curves on the cycle graph</li>
<li>Set alarms around peak values of the flow or temperature of the coolant</li>
<li>Set excessive rejects to stop the machine if the flow or temperature of the coolant rejects parts more than your set thresholds</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DIN/LX-M</title>
		<link>https://rjginc.com/product/din-lx-m/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:58 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/din-lx-m/</guid>

					<description><![CDATA[Lynx™ Communication Adapter  &#8211; Shielded The DIN/LX-M is a Lynx to DIN rail communications module that acts as an interface between standard Lynx cables and Lynx DIN rail mounted modules when not using an ID7-M-SEQ. This DIN rail module is shielded to ensure high quality data even in rugged molding environments. It is designed to be [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Lynx<sup>™</sup> Communication Adapter  &#8211; Shielded</p>
<p>The DIN/LX-M is a Lynx to DIN rail communications module that acts as an interface between standard Lynx cables and Lynx DIN rail mounted modules when not using an ID7-M-SEQ. This DIN rail module is shielded to ensure high quality data even in rugged molding environments. It is designed to be used with RJG&#8217;s process control systems and to be mounted on standard 35 mm DIN rails often found in machine panels.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>IA1-M-V</title>
		<link>https://rjginc.com/product/ia1-m-v/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:58 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/ia1-m-v/</guid>

					<description><![CDATA[<table class="product-specs">
<tbody>
<tr>
<td style="width: 50%;" width="50%">All Modules</td>
<td>Max. Temp. (Operating) 140° F</td>
</tr>
<tr>
<td rowspan="3">IA1-M-V
1 Analog Input</td>
<td>0-10 VDC</td>
</tr>
<tr>
<td>Accuracy ±1%</td>
</tr>
<tr>
<td>Electrically Isolated Input</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Lynx<sup>™</sup> Analog Input Module &#8211; Shielded</p>
<p>This module accepts 0-10V DC signals from analog sensors and equipment in order to integrate them into RJG&#8217;s process control systems. This din-rail module is shielded to ensure high quality data even in rugged molding environments. Examples of sensors that can be used with this module include: electric machine injection pressure, temperature, dew point, and plastic pressure.</p>
<p>Once mounted, the connectors allow the unit to be interfaced with other Lynx DIN rail modules and the process control system. Each machine panel installation of one or more DIN rail module requires either an ID7-M-SEQ or a DIN/LX-M to terminate the DIN rail module chain.</p>
<p><strong>Features and benefits:</strong></p>
<ul>
<li>Easier installation and troubleshooting</li>
<li>Increased immunity to interference in electronically noisy environments</li>
<li>Convenient 35 mm DIN rail mounting</li>
<li>Removable/replaceable cables</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ID/LX1-S</title>
		<link>https://rjginc.com/product/id-lx1-s/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:58 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/id-lx1-s/</guid>

					<description><![CDATA[LYNX MOLD IDENTIFIER The ID/LX1-S Mold Identifier is a mold mountable identifying device that allows molds without cavity pressure sensors to utilize the mold identifying features of RJG’s process control systems. By connecting directly into the Lynx™ sensor network, the Mold Identifier can prevent selection of the wrong mold at job start. It also frees the [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>LYNX MOLD IDENTIFIER</p>
<p>The ID/LX1-S Mold Identifier is a mold mountable identifying device that allows molds without cavity pressure sensors to utilize the mold identifying features of RJG’s process control systems. By connecting directly into the Lynx<sup>™ </sup>sensor network, the Mold Identifier can prevent selection of the wrong mold at job start. It also frees the operator from having to manually select templates and setup data.</p>
<p><strong>Features and benefits:</strong></p>
<ul>
<li>Enables the process control system to automatically identify molds and load all setup information for a particular mold without cavity pressure sensors</li>
<li>Production is more efficient with automatically loaded templates and setup data</li>
<li>Maximum operating temperature is 140° F</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ID7-M-SEQ</title>
		<link>https://rjginc.com/product/id7-m-seq/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:58 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/id7-m-seq/</guid>

					<description><![CDATA[<table class="product-specs">
<tbody>
<tr>
<td>All Modules</td>
<td>Max. Temp. (Operating) 140° F</td>
</tr>
<tr>
<td rowspan="2">ID7-M-SEQ
7 Sequence Inputs</td>
<td>Maximum Input Voltage 36 VDC, Minimum Trigger-On Voltage 18 VDC</td>
</tr>
<tr>
<td>Electrically Isolated Inputs</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Lynx Sequence Module  &#8211; Shielded</p>
<p>Once wired to the molding machine, this module provides the system with machine timing sequences, including injection forward, screw run, mold closed, first stage, and mold opening. This DIN rail module is shielded to ensure high quality data even in rugged molding environments. .</p>
<p><strong>Features and benefits:</strong></p>
<ul>
<li>Easier installation and troubleshooting</li>
<li>Increased immunity in eletrically noisy environments</li>
<li>Convenient 35 mm DIN rail mounting</li>
<li>Easy-to-read status LEDs</li>
<li>Removable/replaceable cables</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/?utm_source=w3tc&utm_medium=footer_comment&utm_campaign=free_plugin

Page Caching using Disk: Enhanced 

Served from: rjginc.com @ 2026-06-09 01:28:56 by W3 Total Cache
-->